国产自慰在线资源|国产精品亚洲中文欧美|亚洲欧美日韩精品专区|在线免费国产视频一区二区|免费一级A级高清毛片人妻|亚洲欧美在线制服丝袜国产|伊人久久大杳蕉夜夜揉夜夜爽|最新哺乳亚洲AV日韩AV二区

EPC Products Teaching and Research Laboratory Equipment Thermodynamics TH3 Saturation Pressure
產(chǎn)品中心
TH3 Saturation Pressure

Model:TH3

Use:

Standard:

Related Products

Description


A bench top unit designed to introduce students to the characteristics of saturated water vapour.
The apparatus is equivalent to a Marcet Boiler, with an additional throttling calorimeter and a pipe loop, which enables saturated steam to
be returned to the base of the boiler as condensate.
Pure water in the boiler is heated to its boiling point using a pair of cartridge heaters with variable power control. A sight glass on the front
of the boiler enables the internal processes to be observed, namely boiling patterns at the surface of the water, and also permits the water
level in the boiler to be monitored.
Saturated steam leaving the top of the boiler passes around the pipe loop before condensing and returning to the base of the boiler for
reheating. The operating range of the boiler and loop is 0 - 7 bar. The top limb of the pipe loop incorporates a Platinum Resistance Thermometer
(PRT), temperature sensor and an electronic pressure sensor to measure the properties of the saturated steam. A flling point on the top limb
enables the loop to be flled with pure water and permits all air to be vented safely before sealing the loop for pressurised measurements.

A vapour o?take, with isolating valve, enables steam from within the loop to be passed through a throttling calorimeter, the purpose of which
is to demonstrate how the dryness fraction of the saturated steam in the loop can be determined.
The steam expands to atmospheric pressure as it is throttled and a second PRT temperature sensor measures the temperature of the
steam following expansion.
The apparatus is designed for safe operation with a pressure relief valve set to operate if the pressure rises above the working pressure and a
Bourdon gauge that remains operational when power is disconnected from the electrical console.
All power supplies, signal conditioning, circuitry etc. are contained in anelectrical console with appropriate current protection devices and an
RCD for operator protection. Readings from the sensors are displayed on a common digital meter with selector switch and all corresponding
signals are routed to an I/O port for connection to a PC using an optional parallel interface/educational software package.


Project Case
Solution
Download
相關(guān)標(biāo)簽
Armfield,TH3,Saturation Pressure